Putting the Drive Back
Together
PowerFlex 400 Frames D-H Replacement Procedure for Main Control Board
6. Connect the ribbon cable to the new control board.
Make sure the ribbon cable connector is fully seated on the
IMPORTANT
main control board connector.
7. Check that all of the cables are properly seated.
Frame D
• Place the front cover back to its original position and torque the two
captive cover screws to about 1.0...1.2 N-m (8.9...10.6 lb.-in.).
Frame E
• Place the front cover back to its original position and torque the four
captive screws to about 1.0...1.2 N-m (8.9...10.6 lb.-in.).
Frame F
• Close the door and turn the latch clockwise.
Frame G
• Install the front cover and torque the four captive screws to about
1.3...1.5 N-m (11.5...13.3 lb.-in.).
Frame H
• Install the front cover and torque the four captive screws to about
1.2...1.8 N-m (10.6...15.9 lb.-in.).
Publication 22C-SB003A-EN-P – August 2008