C2SL42
NON-COMBUSTIBLE CONSTRUCTION
Insulated Jacket NOT Required
24"
24"
20 1 /2"
OPENING
DEPTH
10 1 /4"
OPENING
HEIGHT
INCLUDING
COUNTERTOP
DOORS / DRAWERS
 Combustible material can not be within 24" of the grills frame
 This applies to all directions - horizontal & vertical
 Shaded area above on "TOP VIEW" illustrates the 24" minimum
requirement (not to scale for rendering purposes)
 The grill is designed to hang from the counter top with no support
underneath
 Minimum rear clearance for the hood to open is 2"
 If you have a wall/partition behind the grill, the minimum rear clearance
to that wall should be at least 7" to allow for ventilation of the exhaust
 Regardless if you are using a combustible or non-combustible building material, you must include at least two vents within
the island.
 These vents must be at least 20 sq. in. each and allow fresh air to move from the grill cabinet to the exterior environment.
 For a propane setup, the vents should be installed lower as propane is heavier than air.
 For a natural gas setup, the vents should be located higher in the island, as natural gas is lighter than air.
 Do not locate the two vents on the same wall of the island. Cross ventilation is key to allow any excess heat or trapped
gas to dissipate.
Important Note to Installer:
requirements and consumer guidelines. Please refer to your Owners' Manual prior to installing or operating your built-in grill.
1 1 /2"
GRILL
OPENING
TOP VIEW
1 5 /8"
24"
2 1 /2"
G
GAS
1 1 /2"
CONNECTION
GRILL
2 1 /2"
OVERHANG
39 1 /2"
OPENING WIDTH
2 1 /2"
1 1 /2" MIN
G
2"
OPENING
OPENING WIDTH
HEIGHT
FRONT VIEW
This file is not intended to replace your Owners' Manual which contains specific safety
www.coyoteoutdoor.com
INSTALL GUIDE
COMBUSTIBLE CONSTRUCTION
Insulated Jacket Required - Model # CJAKTCS42
11"
OPENING
HEIGHT
INCLUDING
COUNTERTOP
 If using combustible material within 24" of the grill frame, you MUST use
the corresponding Coyote Insulated Jacket
 Using a insulated jacket, does not waive any other standard installation
procedure (ventilation, connections, etc)
 The jacket is designed to hang from the counter top with no support
underneath
 Minimum clearance for hood to open is 2"
 If you have a wall/partition behind the grill, the minimum rear clearance
to that wall should be at least 7" to allow for ventilation of the exhaust
Ventilation Requirements:
LINER
OPENING
TOP VIEW
4 1 /8"
G
GAS
22 1 /8"
CONNECTION
OPENING
4 1 /8"
DEPTH
42 1 /4"
OPENING WIDTH
4 1 /8"
G
2 3 /4"
DOORS / DRAWERS
OPENING WIDTH
FRONT VIEW
7 /8"
1 3 /4"
7 /8"
JACKET
OVERHANG
1 1 /2" MIN
OPENING
HEIGHT