TroUBleShooTinG (continued)
problem
Unit only leaks water when
powered off.
Unit only leaks water when
powered on.
No heat and the Green Ready Light flashes
continuously.
Unit does not operate, power switch is on, but
light is off.
Green Ready Light and Yellow Steaming Light
turn on and off intermittently.
P/N 1010698 Rev. I 03/12
possible Cause
Solenoid Valve is leaking due to debris
trapped within its plunger and seat.
Solenoid Valve is installed incorrectly.
Control Board inoperable or problem-
atic.
Generator is open.
Solid State Relay not closing.
Control Board inoperable or problem-
atic.
Loose, burnt, or broken wires in heater
circuit.
Circuit is wired incorrectly.
Unit unplugged.
Circuit breaker is off.
Power Cord defective or
inoperable.
Power Switch defective or inoperable.
Hi-Limit is tripping because of an over-
heating Generator.
Hi-Limit is tripping prematurely.
11
Corrective action
Disassemble the Solenoid Valve and clean out the plunger.
Reassemble and test. If the a leak is still present, replace
the Solenoid Valve.
If the Solenoid Valve was replaced, verify that the "IN"
and "OUT" labels on the valve correspond to the water
flow.
If 24 VAC is measured across the Solenoid Valve Coil
for over 2 seconds (with wires still attached to the coil),
replace the Control Board.
Verify that there are 13 Ohms for a 208 volt generator
and 17.5 Ohms for a 240 volt generator (plus or minus 1
Ohm). Replace if the generator fails test.
Verify that there is 7-10 VDC on relay
terminals 3 (+) 4(-). If present, check for line voltage
across relay terminals 1 and 2.
If present, replace the relay.
Verify that there is 7-10 VDC on terminals T5 & T3. If not
present, replace the Control Board.
Repair or replace wires.
Verify that all wiring matches the Wiring Diagram in this
manual.
Plug Power Cord into the appropriate outlet.
Reset the circuit breaker.
Check for continuity.
Verify that the generator surface temperature is between
380°F–420°F. If the temperature is above 420°F, contact
your maintenance person or Authorized Service Agency.
If the Hi-Limit trips within 380°F–420°F, replace the
Hi-Limit thermostat.