Before installing this equipment please read these instructions carefully. Take care: this
equipment contains glass, handle with care! During maintenance or repairs always
disconnect the plug from the socket!
Operation
Ozone has been used for decades for disinfecting drinking water and for purifying air. This
substance has very strong oxidation and sterilisation properties on all organic substances and
takes away unpleasant odours. This makes it one of the most effective means of sterilisation for
water treatment. UV-C radiation and ozone together form the perfect combination for making pond
water immaculately clean and rich in oxygen. Ozone and UV-C kill algae, viruses and bacteria.
The use of ozone is a natural process which is artificially imitated by the AquaForte UV-C Redox.
This equipment consists of an air pump, a UV-C / ozone combination lamp and a static mixer. The
air pump carries air past the combination lamp which produces about 0.6 grams of ozone. The
loaded air is mixed with water in the static mixer where an oxidation process takes place. Once
disinfection has taken place then the water mixed with ozone is carried past the combination lamp
again but this time there is a quartz glass housing as a partition. The water is exposed to UV-C
radiation (25 Watts UV-C Output) so that nearly all algae, bacteria and viruses are killed. The UV-C
radiation also completely breaks down any residual ozone. The equipment produces ozone which is
100% safe; there is no ozone left in the water flowing out.
The AquaForte UV-C Redox increases the capacity of the pond filter and enriches the pond water
with oxygen thus creating a healthy environment for Koi carp and plants.
General
Check the values for your water regularly. Large swings in the pH values are not good for the
equipment. The recommended value is 7.2 – 7.4.
Regular checking of the Redox value of the water is recommended. The equipment must be
switched off at a Redox value which is above 400 mV.
Safety
- This device contains a UV-C lamp. This lamp produces harmful radiation. Direct contact can be
harmful to eyes and skin. Check the operation of the UV lamp only through the transparent
connecting piece. The UV lamp also generates ozone which smells strongly even in very small
quantities. Higher concentrations of ozone can be harmful to the eyes, nose and skin. You should
therefore always check the system for leaks. Proper installation and the correct positioning of the
O-rings are of great importance.
- Turn the lamp off if no water is flowing in order to prevent overheating.
- If the system is not used during the winter months then remove the equipment because of the
danger of it being frozen.
- Always put the power plugs for the equipment into a socket with a cover (photo 1.)
- In the event of a permanent connection to the electricity supply net there must be compliance
with the instructions of the power company. In the event of any doubt about the connections,
consult a certified electrician or the power company. Always work with a earth leakage circuit
switch.
- The equipment should be turned off when water treatment or medications are being used.
Installation (photo 2 & 3)
- Never submerge this equipment in water. Always install in a dry and well-ventilated area.
- Determine the desired input and output side of the device. Standard delivery is with the input on
the right side. If you wish to change this then undo the unit including the pre-switching device (A)
from the plate and remove the plate for the air pump (B). Turn the plate round and refasten all the
parts again in the opposite direction.
- Take the air pump out of the packaging and turn the supplied double plug (C) in the air pump
(the supplied parts in the bag are not used in the ozone application). Put the air pump on the plate
and connect the 2 air hoses to the pump; one air hose goes to the UV-C device (D) and the other
leads to the static mixer (E).
- Fasten the device vertically with a space of at least 30cm being available on the underside for
any maintenance. There must be about 1.5m space at the top so that the lamp (F) can be replaced