Aqua Logic DS-4-WCMD Panduan Instalasi dan Pemeliharaan - Halaman 8
Jelajahi secara online atau unduh pdf Panduan Instalasi dan Pemeliharaan untuk Pendingin Aqua Logic DS-4-WCMD. Aqua Logic DS-4-WCMD 9 halaman. Delta star water-cooled marine duty in-line water chillers
Specifications
Aqua Logic Delta Star Chiller features:
•
Titanium heat exchanger for use in fresh and saltwater applications.
•
Included Protective cover
•
Made in the USA
•
Limited 1-year warranty
Model
HP
BTU
DS-4-WCMD
1/3 4050
DS-5-WCMD
1/2 6000
DS-6-WCMD
1/2 6000
DS-7-WCMD
3/4 9500
DS-8-WCMD
3/4 9500
DS-9-WCMD
1
12000 230
DS-10-WCMD
1.5 21000 230
*
The condenser seawater flow rate is based on 55-60 °F entering water temperature. The condenser
head pressure is maintained by metering the water flow via gate valve.
Volts AMP Refrigerant Evaporator
115
7.2
R-134A
115
9.5
R-134A
230
4.8
R-134A
115
13.0
R-134A
230
7.0
R-134A
7.2
R-134A
10.5
R-417A
Copyright© 2016 Aqua Logic, Inc. Effective date of 1/2016
Condenser
Evaporator
Flow
*Flow
(gpm)
(gpm)
FIPT
10-20
3-5
12-25
3-5
1½"
12-25
3-5
1½"
15-30
5-10
1½"
15-30
5-10
1½"
20-35
5-10
1½"
25-40
10-15
1½"
Dimensions
*
Condenser
I/O
(LxWxH
I/O
inches)
FIPT
¾"
¾"
23 x 14 x 14
1½" / ¾"
24 x 16 x 16
1½" / ¾"
24 x 16 x 16
1½" / ¾"
25 x 21 x 15
1½" / ¾"
25 x 21 x 15
1½" / ¾"
27 x 24 x 15
1½" / ¾"
31 x 26 x 19
Weight
(lbs)
75
125
125
155
155
165
225
8