MILES OR KILOMETERS.
Hold down the left button for 12 seconds until the test pattern appears
and all stored data is cleared. Four seconds after releasing 'mi' or 'km'
flashes. Press the right button to switch between miles and kilometers,
then complete calibration. With the Cyclometer 25 you can change be-
tween miles and kilometers without erasing stored data. Hold the left but-
ton in Total Distance (D) for six seconds and release when 'mi' or 'km'
flashes. Switch between units with the right button. Stored maximum and
average speeds and distance data are automatically converted to the units
chosen when you use this method. Exit by pressing the left button.
CALIBRATION.
from the table, or measure tire circumference by the precise calibration
method. Reach calibration from the Trip Distance function (d). Cyclometer
15: hold the left button until the calibration number 2155 shows in the
lower display and its right digit blinks (8 seconds). Cyclometer 25: hold the
Change the blinking digit
left button until the calibration number 2155 shows in the lower display (4
of the calibration number
seconds), release, then hold again 4 seconds until the right digit of the cali-
with the right button
bration number blinks. Change the number with the right button. Press the
left button to go to the next digit. After adjusting all the digits, press the left
button to exit. To check the calibration number, hold the left button in Trip
Distance. After 4 seconds the calibration will appear, and it will remain dis-
played for 4 seconds after you release the button.
CLOCK SET AND POWER SAVER
SETTING THE CLOCK.
ton in any function to display the clock. Hold down the left button then
press the right button to reach clock adjust. The right digit will blink.
Change it with the right button. Press the left button to go to the next
digit. When you adjust the left digit, it will not change in the display.
You will have to confirm that this digit is correct after you exit clock set.
If it is incorrect, return to clock set, go to the left digit, and adjust it again
with the right button. Note that you cannot set the clock when the Cy-
clometer 25 is asleep with only the clock displayed.
AUTOMATIC POWER SAVER.
and no wheel movement has been detected for 10 minutes, the display
will go blank (Cyclometer 15) or display only the clock (Cyclometer 25).
Power consumption is reduced by 50%. The normal display returns when
a button is pressed or the bicycle is moved.
Cyclometer 25 power
saver. Cyclometer 15
screen is blank.
ALL CLEAR.
You can clear Total Distance manually by holding down
the left button in the Total Distance (D) function until the test pattern
appears (10 seconds). This erases all stored data and resets the calibration
number to 2155 mm (Cyclometer 15). Calibration number is retained
with all clear in Cyclometer 25.
Go to the Total Distance (D) function.
Find the calibration number that matches your tire size
(Cyclometer 25). Hold down the right but-
After no buttons have been pressed
CALIBRATION
CALIBRATION NUMBERS.
ters. This table is based on popular tire brands and assumes recommended inflation pressure and
a rider weight of 165 lbs. (75 kg). To account for your unique combination of weight, tire pressure,
and tire model, measure your tire circumference.
Tire Size
Number
20 x 1.75
1528 mm
24 x 1
1753
600 tubular
1759
650 tubular
1929
26 x 1
1913
26 x 1.25
1952
26 x 1.5
1986
Calibration number equals wheel circumference in inches multiplied by 25.4, or in millimeters.
PRECISE CALIBRATION.
tire's 'rolling circumference' by the following method: Inflate your tires to your usual riding pres-
sure. Mark the ground under the valve stem when the stem is at its lowest point. Get on the bicycle
and have a helper push you in your normal riding position until the valve stem returns to its lowest
point. Take care that the tire travels in a straight line. Mark below the stem again, then measure the
distance in inches between the marks. Multiply your measurement by 25.4 to convert your measure-
ment to millimeters and get your calibration number. Record numbers for your different bicycles
and wheels below.
Bike/Wheel______________________________ Calibration #:____________________________
Bike/Wheel______________________________ Calibration #:____________________________
BATTERY & TROUBLESHOOTING
INSTALLING A NEW BATTERY.
move the battery, pry up the cap on the back
of the Cyclometer with a screwdriver. Install
the new battery with its positive (+) side to-
ward the cap, then press in the cap with your
thumb. Use only an Avocet Cyclometer 15/
25 battery or equivalent (see specifications).
Removing the battery erases all stored data
and resets the calibration number to 2155.
After installing a battery, the Cyclometer dis-
plays the test pattern briefly, then goes into
miles/kilometers setup.
The calibration number is wheel circumference in millime-
Tire Size
Number
Tire Size
26 x 1.95/2.0
2045 mm
700 x 28
26 x 2.1
2056
700 x 32
26 x 1
3
/
2068
700 x 38
8
700C tubular
2083
27 x 7/8
700 x 20
2081
27 x 1
700 x 23
2087
27 x 1 1/8
700 x 25
2091
27 x 1 1/4
For the most precise calibration of your Cyclometer, measure the
TROUBLESHOOTING
To re-
Speed and distance seem too high or too low
Check calibration number
Confirm calibration number by tire roll-out
Check that receiver is parallel to nearest spoke
Check spacing between receiver and transmitter
No speed or distance
Check transmitter/receiver alignment and spacing
Check contacts on back of Cyclometer and on mount
and clean with a pencil eraser if necessary
Check for broken wire
No Average Speed, Trip Distance, or Ride Time
Hold right button then press left button in Total
Distance (D) to reset Auto Start-Stop
No display or display dim
Replace battery
Incorrect data or unusual display
Total reset–hold left button in Total Distance (D)
function until test pattern appears
Incorrect display after a new battery is installed
Remove battery, then reinstall after 15 seconds
Number
2096 mm
2116
2159
2077
2105
2123
2142