Pict. 5: The refill hose has to be attached above the water level. If immersed, water could flow from the filter
tank into the reservoir or vice versa until both water levels are equal. For the same reason, the reservoir should
not be higher than the outlet of the refill hose, as otherwise uncontrolled water may run on.
Pict. 6: Mounting of the float switches N1 and N2 by using the supplied holder. The floats have to point upwards.
1. Float switch N1
2. Overflow protection float switch N2
3. Sensor holder lower part
4. Sensor holder upper part
5. Cable holder
6. Fixing screws for the holder
7. Fixing nuts for float switch
Available spare parts: Please refer to www.aqua-medic.de.
The refill unit turns off as soon as the water has sufficiently raised the float switch N1. In case this sensor fails,
the water rises up to the float switch N2 which then interrupts the refilling. The sensor N1 has a delay function
that suppresses a constant on and off with wave motions. If the refill reservoir is empty, an audible alarm will
sound.
8