Aqua One Arctic 1/6HP Petunjuk Manual - Halaman 5
Jelajahi secara online atau unduh pdf Petunjuk Manual untuk Pendingin Aqua One Arctic 1/6HP. Aqua One Arctic 1/6HP 6 halaman.
Trouble Shooting
CONTROL PANEL DOES NOT COME ON
1. Check the chiller is plugged in.
2. Check the switch is in the "on" position.
3. Unplug the unit. Unscrew the fuse on the chiller and
verify that it is not blown. Replace if necessary. The
fuse is located beneath the power cable and the power
switch in the location shown below.
THE CHILLER IS NOT COOLING THE
WATER OR NOT COOLING ADEQUATELY
1. The chiller is not placed in an area with sufficient
ventilation. Ensure the air intake and outlets are not
obscured.
2. The radiator needs to be cleaned. Refer to
maintenance instructions.
3. The set temperature is higher than the water
temperature. Check the set temperature and adjust if
necessary.
4. The water flow is too slow or too fast. Ensure flow rate
through the chiller is as per the recommendations.
THERE IS NOISE COMING FROM THE
CHILLER UNIT
1. The chiller is not placed on a level surface.
2. The noise is being caused by vibrations due to
objects sitting on or leaning against the unit. Ensure
nothing is in direct contact with the chiller.
AN ALARM IS SOUNDING AND THE
DISPLAY IS FLASHING
1. If the display is flashing "LLL" the temperature is
below the minimum operating temperature (0°C).
Switch the unit off until air temperature is above this
temperature.
2. If the display is flashing "HHH" the temperature is
above the maximum operating temperature (50°C).
Switch the unit off, check for obstructions around the air
intake/outlets. The unit will not operate if air temperature
is above the maximum operating temperature.
Specifications
Chiller Model: Arctic 1/6HP
Dimensions: 39x32x46cm
Max Aquarium Volume: 300L
Flow Rate: 800-2200L/hr
Inlet/Outlet Size: 19mm
Power Requirements: 220 ~ 240V
Power: 1/6HP
Refrigerant: R134A
Suitable: Marine
switch
cable
Chiller Model: Arctic 1/3HP
fuse
Dimensions: 46x39x52cm
Max Aquarium Volume: 650L
Flow Rate: 1200-3600L/hr
Inlet/Outlet Size: 19mm
Power Requirements: 220 ~ 240V
Power: 1/3HP
Refrigerant: R134A
Suitable: Marine
Chiller Model: Arctic 3/5HP
Dimensions: 48x52x52cm
Max Aquarium Volume: 1000L
Flow Rate: 1800-4800L/hr
Inlet/Outlet Size: 19mm
Power Requirements: 220 ~ 240V
Power: 3/5HP
Refrigerant: R134A
Suitable: Marine
Disposal of used Electrical & Electronic Equipment
(Applicable in the European Union and other
European countries
systems)
equipment by arranging to return it to a designated
collection point for the recycling of waste electrical
and electronic equipment. By separating and recycling
your waste equipment at the time of disposal you will
help to conserve natural resources and ensure that the
equipment is recycled in a manner that protects human
health and the environment. For more information
about recycling this product, please contact your local
city office, your household waste disposal service or
the shop where you have purchased the product.
7
with
separate
This symbol on the product or on its
packaging indicates that the product
must not be disposed of with normal
household waste. Instead, it is your
responsibility to dispose of your waste
GB
collection