Installation (continued)
Figure 2
PRIOR TO PRESSURE TESTING
□ Securely tighten knobs, drain fittings, lid, and system
accessories.
□ Air may collect at the highest point in the plumbing
system. Normally an air purge valve is provided with the
pool filter. Consult your pool filter instruction manual for air
purging instructions.
□ The basket lid must be rotated and locked into position as
indicated in Figure 3.
□ Test system at a water pressure of 25 psi or less.
□ Water Temperature for test must be less than 100° F.
□ After 24 hours visually check the system for leaks.
POOL PUMP SUCTION REQUIREMENTS
WARNING: Pump suction is hazardous and can trap, drown or disembowel bathers. Do not use or operate swimming pools or spas if a
suction outlet cover is missing, broken, or loose. Follow the guidelines below for a pump installation which minimizes risk to users of pools and
spas.
DANGER: Ground the motor before connecting to electrical power supply. Failure to ground the motor may cause severe or fatal electrical
shock hazard.
ENTRAPMENT PROTECTION
The pump suction must be designed to eliminate the possibility of suction entrapment or hair entrapment/entanglement.
SUCTION COVERS
All suction inlet covers must be maintained and replaced if cracked, broken, or missing. See Figure 2 for outlet cover certification
Figure 3 - Clamp rings
5
Please contact 1-877-278-2797 for further assistance.