Aqua PRO VIGOH80 Petunjuk Manual - Halaman 5
Jelajahi secara online atau unduh pdf Petunjuk Manual untuk Pemanas Kolam Renang Aqua PRO VIGOH80. Aqua PRO VIGOH80 11 halaman. Heat pump pool and spa heater
TIME CLOCK OVERRIDE (TCO)
OPERATION
All wiring and
electrical connections
must be performed by a qualified
electrician. Installation must be in
accordance with local and national codes.
This section allows you the option of
using an existing time clock with the
heat pump. If you do not have a time
clock, please refer back to the Time
Clock Eliminator section.
ACTIVATING AND SETTING SYSTEM
RUN TIME – TCO OPERATION
To set the run time of the system, push
the "SET" button repeatedly until
"FIL" displays. Then using the "UP"
and "DOWN" arrows, set the hours to
"2". The range of hours is "off" to 2,
3, 4.... up to 23 hours to "on".
INSIDE
HEAT
PUMP
BREAKER
JUNCTION
BOX
Figure 4 - TCO wiring diagram (optional)
leaves the factory with the "FIL"
mode set to "OFF".
Figure 5 - Bonding location
5
T3
T4
CONTACTOR
FOR THE
TIME
CLOCK
OVERRIDE
L3
L4
TIME
CLOCK
m
GROUNDING & BONDING
s
Grounding and bonding are required
The unit
for personal safety and unit
protection purposes. Please follow all
applicable laws and regulations.
FILTER
PUMP