Step 11
The next setting you'll see is RT (Regen Time). By default this will be set to 2:00 AM.
Customize this time according to your schedule where you won't be using any water or
other system backwashing. It takes a couple hours for your system to regenerate.
Press the Cycle button to advance to the next step.
Step 12
The next setting you'll see is BW (Backwash). Set the value to 10.
Press the Cycle button to advance to the next step.
Step 13
The next setting you'll see is BD (Brine Draw). Set the value to 60.
Press the Cycle button to advance to the next step.
Step 14
The next setting you'll see is RR (Rapid Rinse). Set the value to 10.
Press the Cycle button to advance to the next step.
Step 15
The next setting you'll see is BF (Brine Fill). Set the value 12 minutes to 9x48, 15 minutes
to 10x54, 19 minutes to 12x52.
Press the Cycle button to advance to the next step.
Step 16
The next setting you'll see is FM (Flow Meter). Set the value to t0.7.
Press the Cycle button to accept and you're all set with programming your Valve.