Overflow operation
(normal operation)
1 Overflow channel
2 Swimming pool
3 Main drain
ECO switch:
There are three options:
1. Auto operation:
In this position, as a function of air and water temperatures, it is deter
mined whether drainage will take place directly via the pool (economy
mode) or via the overflow channel. As soon as the pool cover is opened,
the system goes into overflow mode. (The limit switch must be connec-
ted to terminals 71/72)
2. Main drain operation (economy mode):
The Besgo valve is always in the economy mode and drainage is via the
main drain irrespective of temperature and whether the pool cover is
open or closed.
3. Overflow tank operation:
The pool is always drained via the overflow channel – irrespective of
temperature and whether the pool cover is open or closed.
Heating key:
Auto: heating operates according to the programmed filter time
Off:
heating is switched off
On:
if this light is lit the heating is operating. The set temperature
has not yet been reached.
Filter key:
Auto: filter operates according to the programmed filter time
Off:
filter is switched off
On:
filter operates permanently
Economy mode
4 Overflow tank
5 Besgo 3-way valve
6 Pump
7 Filter