CPG 351FGC100DD Panduan Servis - Halaman 7

Jelajahi secara online atau unduh pdf Panduan Servis untuk Oven CPG 351FGC100DD. CPG 351FGC100DD 18 halaman. Gas powered convection ovens
Juga untuk CPG 351FGC100DD: Panduan Pengguna (12 halaman)

CPG 351FGC100DD Panduan Servis
Service Manual
351FGC100(L/N) | 351FGC200(L/N)K
351FGC100DD(L/N) | 351FGC200DD(L/N)K

Transformer

Check for 120 volts at terminals (Fig. 13A).
1.
Check for 24 volts at terminals (Fig. 13B). If voltage is
2.
not correct, replace.
24 volts goes to thermostat, 'HEAT ON' lamp and gas
3.
solenoid valve.
Check for any discoloration or deformations of electrical
4.
connections. If any are found, replace connections.

Ignition Module

S1 connection - 120 VAC surface igniter
L1 connection - 120 VAC input power (live)
W connection - Fan motor then thermostat
V1 connection - Gas solenoid valve
GND connection - Ground
S2 connection - Flame sensor
Check that module has power, check for 120 volts from L1 connection to GND connection and
also from L1 connection to a Neutral wire on the back of unit (Fig. 15 & 16).
Red Light Definitions:
- Solid red, no blinks: control fail, replace ignition module
- 2 blinks: flame on, but no call for heat, check thermostat
- 3 blinks: no flame, ignition locked out, check ignition sequence parts (surface igniter, gas
solenoid valve, flame detector)
Fig. 14
www.cookingperformancegroup.com
Fig. 15
Fig. 13
A
B
Fig. 16
7