ABATEMENT HEPA-AIRE HA700A Buku Petunjuk - Halaman 11

Jelajahi secara online atau unduh pdf Buku Petunjuk untuk Pembersih Udara ABATEMENT HEPA-AIRE HA700A. ABATEMENT HEPA-AIRE HA700A 17 halaman. Portable air filtration unit

TROUBLESHOOTING GUIDE

PROBLEM
NO RESPONSE
WHEN THE
POWER IS
TURNED "ON".
CIRCUIT
BREAKER FOR
BUILDING
"TRIPS".
FILTER CHANGE
INDICATOR "ON".
Note: If unit does not start or malfunctions after carefully following the Troubleshooting Guide, call Abatement
Technologies' service department at +1 800-634-9091 (U.S.) or +1 905-871-4720 (Canada) for assistance.
COMPONENT REPLACEMENT AND CARE OF THE UNIT
Warning: To reduce the risk of fire, electrical shock or personal injury, always turn the unit "OFF" and
disconnect power cord from supply receptacle before removing the control panel, replacing the HEPA filter and
before cleaning or servicing the unit. The HA700 and HA700A is equipped with an automatic restart motorized
impeller that will restart without warning after a temporary power interruption or recovery from a thermal
overload (overheating) condition. Keep clear of the motorized impeller at all times to reduce the risk of injury.
Occasionally a defective component will cause the unit to operate improperly or not at all. Any electrical
component can fail. Refer to the Wiring Diagram and Wiring Schematic to diagnose the failure of any
component. Diagnostics should only be performed by a technician qualified to service electrical equipment.
The unit should be cleaned with a damp cloth or a water based cleaner/sanitizer. Do not use harsh chemicals,
solvents or detergents to clean the unit.
Warning: Keep electrical components dry as their exposure to liquids poses a safety hazard and can damage
components.
POSSIBLE CAUSE
POWER CORD
UNPLUGGED.
DEFECTIVE POWER CORD.
TRIPPED CIRCUIT
BREAKER.
TRIPPED GROUND FAULT
CIRCUIT INTERRUPTER.
THERMAL OVERLOAD ON
THE MOTOR HAS TRIPPED.
OVERLOADED CIRCUIT.
LOADED FILTERS.
EXCESSIVE
RESTRICTIONS.
CARBON FILTER HAS NOT
BEEN REMOVED FROM
POLYBAG.
SOLUTION
PLUG POWER CORD FIRMLY INTO
ELECTRICAL OUTLET IN WALL.
CHECK ALL CONNECTIONS AND
CONDITION OF ALL CORDS. DO NOT
OPERATE WITH DAMAGED POWER
CORD(S).
RESET BREAKER FOR BUILDING.
RESET 12 AMP BREAKER ON UNIT.
RESET GFCI AT POWER SOURCE.
TURN UNIT "OFF", WAIT 30 MINUTES and
RESTART UNIT.
REMOVE OTHER LOADS FROM CIRCUIT.
RESET CIRCUIT BREAKER.
CHANGE IN ACCORDANCE WITH
OPERATING INSTRUCTIONS.
REDUCE BENDS, LENGTH OF FLEX DUCT
OR ELIMINATE RESTRICTIONS.
REMOVE CARBON FILTER FROM POLYBAG.
10