Abatement Technologies HEPA-AIRE PAS600 Buku Petunjuk - Halaman 8

Jelajahi secara online atau unduh pdf Buku Petunjuk untuk Scrubber Abatement Technologies HEPA-AIRE PAS600. Abatement Technologies HEPA-AIRE PAS600 17 halaman. Portable air scrubber

monitored with a calibrated instrument as per OSHA/CDC requirements. The Abatement Technologies Portable
Pressure Monitors are recommended to ensure that requirements are being met.
Important Note: Do not operate the unit unless the pre-filter(s) and HEPA filter are installed and the filter access
door and panel are in place and closed.

CONTROL PANEL

1. Power Cord. Hardwired, 10 ft 14/3 AWG SJTW power cord for
connection to an electrical outlet.
2. Speed Control Switch. Serves as the power switch and provides
a variable adjustment to the speed of the motorized impeller.
3. Power Indicator. Green light that indicates speed control switch
is "ON" and unit is connected to power source.
4. Filter Change Indicator – Amber light that indicates excessive
restriction on air exhaust or loading of the filter(s) and that filter
change procedures should be followed.
Note : Check the filter loading indicators when the unit is
operating on "HIGH" speed.
5. Circuit Breaker. 12 amp circuit breaker that provides protection
for the unit's electrical components.
6. GFCI Receptacle. Electrical safety device that will trip and stop
the flow of electricity if leakage of current is detected from the unit
or an electrical device plugged into the GFCI receptacle. The
PAS600 plugged into a 120 V/15 A electrical power supply can
supply a total of 8 amps of electrical power for additional
equipment that is connected to the GFCI receptacle. Do not
exceed this 8 amp limit.
Note : If the equipment connected to the GFCI receptacle draws
more than a total of 8 amps, the circuit breaker on the control panel
and/or the building breaker will trip. This condition can be remedied
only by reducing the total amperage draw.

DAISY CHAINING

"Daisy Chaining" refers to the operation of multiple units on one circuit, with only one of the units plugged into a
120 V/15 A electrical power supply receptacle. Each subsequent unit is plugged into one of the GFCI receptacles
on the prior unit, up to the maximum number allowed based on the amperage draw per unit. The National
Electrical Code limits the total amperage draw of devices operating on one circuit to 80% of full load, which
means that the total amperage draw on a 120 V/15 A circuit, including the unit plugged into the building electrical
power supply receptacle, must not exceed 12 amps.
A total of five PAS600 units, including the unit plugged into the building electrical power supply receptacle, can
be "Daisy Chained" on a 15 amp circuit.

STARTING THE UNIT

1. Check to make sure that the Speed Control Switch is in the "OFF" position. Plug the power cord into a
120 volt AC, 60 Hz, 15 amp supply circuit.
2. Turn Speed Control switch clockwise past the click at the "HIGH" setting to turn power "ON".
3. Set Speed Control switch to desired setting.
Note: Refer to the chart in this instruction manual entitled PAS600 SPECIFICATIONS that lists the
airflows for the PAS600.
Note: In the event of a power failure while the unit is running, or loss of power due to any other cause, after a
brief delay this unit's motorized impeller will re-start when power is restored.
6