Dell PowerEdge 2650 Petunjuk Manual - Halaman 4

Jelajahi secara online atau unduh pdf Petunjuk Manual untuk Laptop Dell PowerEdge 2650. Dell PowerEdge 2650 8 halaman. Activating the integrated raid controller
Juga untuk Dell PowerEdge 2650: Panduan Instalasi (26 halaman), Instal Manual (32 halaman), Pembaruan Informasi (14 halaman), Panduan Instalasi (20 halaman), Instal Manual (40 halaman), Manual Penggantian (28 halaman), Manual (42 halaman), Manual (15 halaman), Manual (42 halaman)

Dell PowerEdge 2650 Petunjuk Manual

Input Requirements

Supply voltage:
Current
consumption:

Kit Contents

AMP 794949-1 connector housing, or equivalent
AMP 350218-1 connector contacts, or equivalent
AMP 2-36161-5 ring-tongue terminal, or equivalent
#6-32 nut equipped with lock washer
Heat-shrink tubing
Required Tools
Wire-stripper pliers capable of removing insulation from size 16 AWG solid or
stranded, insulated copper wire
Three UL 1061 16 AWG black wires (–48 VDC)
Three UL 1061 16 AWG red wires (–48 VDC return)
One UL 1015 12 AWG green/yellow, green with a yellow stripe, wire (ground)
AMP 90296-2 hand-crimping tool, or equivalent
AMP 59824-1 hand-crimping tool, or equivalent
Heat gun

Assembling the DC Input Power Cable

CAUTION: Before connecting safety ground or power cables to the connector,
ensure that the power is removed from the DC circuit. To ensure that the power
is off, locate the circuit breaker on the DC source circuit. Switch the circuit
breaker to the off position and, if available, install an approved safety locking
device to the circuit breaker or switch, to prevent against another person
energizing the circuit.
1-2
Cabli ng Instr u ctions f or t h e –48 V D C
–(48–60) VDC
8 A