INSTALLATION MANUAL FOR ROOM
AIR CONDITIONER
(Split Wall Mounting Type)
For correct installation, read this manual before starting installation. Please save this manual in a safe place.
Only trained and qualified service personnel should install, repair or service air conditioning equipment.
Users should not install the air conditioner by themselves.
Pictures in this manual may be slightly different from the air conditioner you purchased. These pictures
are only sketches.
INSTALLATION PRECAUTION
Installation in the following places may cause trouble. If it is unavoidable to use in such places, please
consult with the dealer:
A place full of machine oil.
A saline place such as coast.
A place full of sulfide g s such as hot-spring resort.
a
Places where there are high frequency machines such as wireless installation, welding machine, and
medical facility.
A place of special environmental conditions.
Indoor Unit
A place where is no obstacle near the inlet and
outlet area.
A
place which can bear the weight of the indoor unit.
A
place which provides the spaces around the
indoor unit as required right in the diagram.
A place 1m or more from TV, radio instrument, in
the center of the room is perfect.
A place which is far from heat, steam and
inflammable gas.
Install the indoor unit on the wall where the height
from the floors more than 2.3 meters.
NOTE:
1.
The appliance shall not be installed in the laundry. All the connection must be in accordance with
national regulations.
2.
For detailed installation acceptance, please refer to your contract with the power supplier if restrictions
do apply for products like washing machines, air conditioners or electrical ovens.
3.
For power details of the air conditioner, refer to the rating plate of the product. Contact your local dealer if
you have any questions.
1. Cutting A Hole and Mounting Installation Plate
Installation Plate and Its Measures (Unit: mm)
Above 150 from
the ceiling
1250
178
815
Above 120 from
the wall
Pipe hole
58
1. Fix the installation plate.
1.
Install the installation plate horizontally on structural
members in the wall with the spaces provided around the
plate.
2.
In case of block, brick, concrete or similar type walls,
make 5mm dia, holes in the wall. Insert clip anchors for
appropriate mounting screws.
3.
Fix the installation plate on the wall.
3. Indoor unit Installation
1.
Pass the piping through the
Upper hook
hole in the wall.
2.
Put the upper claw at the back
Low hook
of the indoor unit on the upper
hook of the installation plate,
Move the indoor unit from side
to side to see that it is securely
hooked.
3.
Push the lower part of the
indoor unit up on the wall.
4.
Piping can easily be made by
lifting the indoor unit with a
Cushioning material
cushioning material at the
remote controller holder side
between the indoor unit and the
wall.
Outdoor Unit
A place, which is convenient to installation and
not exposed to a strong wind.
A place can bear the weight of the outdoor unit
and where the outdoor unit can be held in the
horizontal position.
A place where the operation noise and disc-
harge air do not disturb you neighbor.
A place free of a leakage of combustible gases.
An allowable head level at the connective
piping is less than 5m and length of the
connective piping is up less than 10m.
A place, which provides the spaces around the
outdoor unit as required right in the diagram.
Unavailable to children.
INDOOR UNIT INSTALLATION
1
Hooked Part Hooker Part
257
Above 120 from
the wall
55
2. Cutting a hole.
1.
Determine the pipe hole position
using the installation plate, and drill
the pipe hole (
95mm
) so it slants
slightly downward.
2.
Always use a piping hole cap when
piercing a wall, made of metal lath,
wire lath or metal plate.
4. Electrical Work
Prepare the power source for exclusive with the air conditioner.
The supply voltage must be the same as the rated voltage of the
air conditioner.
Power Supply
Model
220-230V~
60Hz
24000Btu/h
or
220-240V~
50Hz
24000Btu/h
NOTE:
A disconnection device having an air gap contact separation at least
3mm in all conductors should be incorporated in the fixed wiring
according to the National Wiring Regulation.
Caution
Perform the wiring with sufficient capacity.
Installation places legally require a short circuit isolator to be
attached to prevent electrical shock.
Do not extend the power cable code by cutting.
The plug of the air conditioner takes a grounding leg, so clients
should use a grounding socket so that the air conditioner can be
grounded efficiently.
Installation Parts
Part
Name of part
No.
1
Installation plate
2
Clip anchor
3
Mounting screw A ST3.9x25-C-H
4
Remote controller
5
Remote controller holder
6
Mounting screw B ST2.9x10-C-H
6.35( 24000Btu/h)
7
Liquid side
Refrigerant
9.53( 24000Btu/h)
pipe
12.7( 24000Btu/h)
Gas side
16( 24000Btu/h)
Seal
8
9
Drain elbow
Caution
The outdoor unit should not be exposed
to strong wind.
Fix the outdoor unit with
10 anchor
bolts.
A
air inlet
air outlet
Model
A
B
24000Btu/h
560
335
24000Btu/h
590
333
If need suspending installation, consults
the corresponding requirement.
2. Connective Pipe and Drainage Installation
1. Drainage
1.
Run the drain hose sloping downward. Do not
install the drain hose as illustrated below.
Do not form a rise.
Do not put the drain
end into water.
2.
When connecting extension drain hose,
insulate the connecting part of extension
drain hose with a shield pipe.
Wall
Shield pipe
Extension drainhose
Drain hose
Inside the room
1.
Lift the panel, loose the screw then open the Electric Box Cover.
2.
Connect the wires to the terminals on the control board indivi-
dually according to the outdoor unit connection.
AWG(MIN.)
Input Rated Amp
3.
Wrap those cables not connected with terminals with insulation
Power Supply
Connecting
(Switch/Fuse)
cord
tapes, so that they will not touch any electrical components.
cable
32/20A
18
12
32/25A
Q'ty
Cautions on remote controller installation
1
Before installation, operate the remote
8
controller to determine its location in a
reception range.
8
Keep the remote controller at least 1m
1
apart from the nearest TV set or stereo
1
equipment.
2
Do not install the remote controller in a
place exposed to direct sunlight or close
to a heating source, such as a stove.
Note that the positive and negative
poles are right positions when loading
batteries.
4
Remote
Controller
Remote controller
holder
6
5
ST2.9X10-C-H
Mounting screw B
A
B
Loop the connective
Remove the water receiver first
cable.
before connecting the pipes.
NOTICE:
There should be at least two of
the A, B, C direction are free from
blocking.
2. Connective pipe
1.
For the left-hand and rear-left-hand piping,
install the piping as shown. Bend the conne-
ctive pipe to be laid at 43mm height or less
from the wall.
Indoor unit outline
Connective pipe
.
2.
Fix the end of the connective pipe.
Caution
Connect the indoor unit first then the
outdoor unit.
Bend and arrange the pipe carefully.
Insulate both of the auxiliary piping.
Drainage can not annoy your neighbor.
5. Connecting Cables
Panel
Terminal block
1 2(N) S
G
Code wire
Terminal block of indoor unit
To outdoor unit
7
C