Module: OSPF, IPG
If OSPF was configured using the command set ospf dyninterface=stub, to
advertise dynamic interfaces such as PPPoE interfaces as stub links, the
links were not being advertised as expected. This issue has been resolved.
PCR: 40442
Module: IPSEC
When an IPSEC policy is used on a PPP link with iprequest=on, when the
PPP link goes down and IPSEC has traffic to transmit, IPSEC repeatedly
attempts to activate the PPP link again. The frequency of the reactivation
attempts has been reduced.
PCR: 40446
Module: DHCP
In certain situations, if a DHCP client used a DHCP relay agent to request
IP addresses from the router acting as the DHCP server on a different
subnet, it was not be able to renew the IP address allocated to it. This issue
has been resolved.
PCR: 40450
Module: IPG
IGMP entries were sometimes changed to static entries rather than being
deleted when IGMP leaves were received. This issue has been resolved.
PCR: 40451
Module: FIREWALL
The "number of hits" counter in firewall's application rules was not
incremented correctly. This issue has been resolved.
PCR: 40453
Module: PIM
Particular IP packets (unicast destination IP, but multicast destination MAC)
could result in a memory leak, which in some cases could cause the device to
stop responding to the command line. This issue has been resolved.
PCR: 40456
Module: IPG
The enable switch learning command would fail if 802.1X port
authentication was enabled on any of the switch ports. This issue has been
resolved.
PCR: 40458
Module: IPG
The router was accepting network RIP packets from foreign subnets. This
issue has been resolved.
PCR: 40465
Module: PIM6, PIM4
The router could reboot when a user changed the Rendezvous Point
Candidate (RPC) priority in the PIM6 module. This issue has been resolved.