Dell D560F Panduan Pemilik - Halaman 18
Jelajahi secara online atau unduh pdf Panduan Pemilik untuk Server Dell D560F. Dell D560F 33 halaman. Emc vxrail appliances on poweredge servers
Table 16. AC PSU status indicator codes (continued)
Power indicator codes
Inside the system
NOTE:
You may be able to add or replace some hardware components on your VxRail Appliance such as solid state
drives (SSDs), power supplies, and so on. Only qualified personnel should perform these procedures. For other hardware
components, you may need to contact Customer Support to arrange for repair or replacement. Refer to the online support
website or SolVe Online for VxRail for hardware-specific information.
Figure 12. Inside the system
1. Front IO board
(VGA, ESATA, M.2, internal USB port, and smart card
controller)
3. Cabling latch
5. MiniPERC riser
7. Expansion riser 1
● 1 CPU configuration - full height expansion riser
● 2 CPU configuration - low profile expansion riser
(shown)
9. Heat sink and processor 1
11. Hard drive backplane
18
Dell EMC VxRail D Series overview
Condition
different input voltages, they can output different wattages, and trigger a
mismatch.
CAUTION:
If two PSUs are used, they must be of the same type and have the same
maximum output power.
2. Cooling fan
● 1 CPU configuration - 5 fans
● 2 CPU configuration - 6 fans
4. Power interposer board
6. Expansion riser 2
● 1 CPU configuration - N/A
● 2 CPU configuration - low profile expansion riser
(shown)
8. Processor 2
● 1 CPU configuration - blank (shown)
● 2 CPU configuration - processor 2 populated
10. Air shroud