Dell EMC PowerEdge R640 Manual - Halaman 27

Jelajahi secara online atau unduh pdf Manual untuk Server Dell EMC PowerEdge R640. Dell EMC PowerEdge R640 49 halaman. Metro node
Juga untuk Dell EMC PowerEdge R640: Panduan Pemasangan Perangkat Keras (2 halaman)

Dell EMC PowerEdge R640 Manual
The lower overall system-level power draw is a result of the breakthrough system design developed by Dell EMC. The system aims to
maximize performance-per-watt through a combination of energy efficient technologies, optimized thermal designs and intelligent fan
control algorithms. System fan control algorithms use an extensive array of sensors that automatically monitor power and thermal activity
to minimize fan speeds based on system cooling requirements, reducing the power required for cooling.
Topics:

Power consumption and energy efficiency

Thermal and Acoustics
Power supply units
Acoustical design
Power consumption and energy efficiency
With the rise in the cost of energy coupled with increasing data center density, Dell EMC provides tools and technologies to help you realize
greater performance with lower energy cost and wastage. More efficient data center usage can reduce costs by slowing the need for
additional data center space. The following table lists the tools and technologies that Dell EMC offers to help you achieve your data center
goals by lowering power consumption and increasing energy efficiency.
Table 15. Power tools and technologies
Feature
Power supply units (PSU) portfolio
Tools for right-sizing
Power monitoring accuracy
Power capping

Power, Thermal, and Acoustics

Description
Dell EMC PSU portfolio includes intelligent features such as
dynamically optimizing efficiency while maintaining availability and
redundancy. For more information, see, the Power supply units
section.
The Dell Enterprise Infrastructure Planning Tool (EIPT) is a tool that
helps you plan and tune your computer and infrastructure
equipment for maximum efficiency by calculating hardware power
consumption, power infrastructure and storage. Learn more at
Dell.com/calc.
PSU power monitoring improvements include:
Power monitoring accuracy of 1%, whereas the industry
standard is 5%
More accurate reporting of power
Better performance under a power cap
Use Dell EMC systems management to set the power cap limit for
your systems to limit the output of a PSU and reduce system power
consumption. Dell EMC is the first hardware vendor to leverage
Intel Node Manager for circuit-breaker fast capping.
Power, Thermal, and Acoustics
8
27