Table 10. Troubleshooting scenarios (continued)
Issue
No FC connectivity
ES40 shelves not detected
NVRAM not charged
License file is missing or incomplete
42
Installation Troubleshooting
Remedy
● Verify the FC infrastructure is known to be functional
● Verify all FC cables are the correct type and are known to
be functional.
● Verify FC HBA and all FC cables are fully seated.
● Verify all SFPs are fully seated and are known to be
functional.
Verify the SAS HBA and all SAS cables are fully seated.
The NVRAM module takes 2-3 hours to reach 80% charge. If
the NVRAM is not charged to 80% or more, the system will
generate errors and performance is degraded.
● Contact your Dell EMC sales representative.
● Open a license case on the Online Support portal.