Juga untuk Dell PowerEdge 1650: Pembaruan Informasi (44 halaman), Pembaruan Informasi (44 halaman), Panduan Instalasi (44 halaman), Panduan Instalasi (44 halaman), Panduan Instalasi (44 halaman), Panduan Instalasi (44 halaman), Manual (15 halaman), Panduan Instalasi (44 halaman), Panduan Pengguna (34 halaman)

Dell PowerEdge 1650 Petunjuk Manual

Input Requirements

Supply voltage: –(38–60) VDC
Current consumption: 7.5 A
Connecting the –48 VDC Power Cable and

Safety Ground

Remove the #6-32 nut equipped with a lock washer from the grounding post on the
1
back of the system.
Connect the safety ground (green/yellow wire) to the grounding post on the back of
2
the system using the #6-32 nut equipped with a lock washer that you removed in
step 1 (see Figure 1-1).
F i g u r e 1 - 1 .
safety ground wire
1-2
Cabling Instr uctions fo r the –48 VDC
NOTE: If your system is equipped with redundant –48 VDC power supplies, you
must connect both safety ground wires to the grounding post on the back of the
system.
S a f e t y G r o u n d
grounding post
#6-32 nut with
lock washer