Dell PowerEdge 1855 Panduan Pengguna - Halaman 14

Jelajahi secara online atau unduh pdf Panduan Pengguna untuk Server Dell PowerEdge 1855. Dell PowerEdge 1855 33 halaman. Using dell blade servers in a dell poweredge high availability cluster
Juga untuk Dell PowerEdge 1855: Pembaruan Informasi (2 halaman), Panduan Memulai Cepat (12 halaman), Gunakan Manual (44 halaman)

Dell PowerEdge 1855 Panduan Pengguna
 DRAC/MC Module Features
The DRAC/MC provides serial and Ethernet management ports, a status indicator when redundant DRAC/MCs are installed (when available), and status
indicators for the DRAC/MC and for the link to the system's onboard network interface controller (see Figure 1-11). See the documentation for the DRAC/MC
module for specific information on serial port redirection of server modules and switches.
 Figure 1-11. DRAC/MC Module Features
 Table 1-9. DRAC/MC Module Indicators 
 
Indicator Type
Network interface controller link
indicator
 
Network interface controller
activity indicator
 
Primary/secondary indicator
 
 
Fault indicator
 
 
Serial connector
 
DRAC/MC Version 1.1 (or Later) Module
If you have a DRAC/MC version 1.1 (or later) module installed, ensure that you read that product's readme.txt file. It contains updated information, including
system indicator behavior in certain conditions.
 
Important I/O Configuration Considerations
 
CAUTION:
Data loss can result if you perform certain actions on a system in which the I/O bays have not been configured correctly. Specifically,
bay 2 should have an I/O module installed only if an identical module is present in bay 1, and bay 4 should have an I/O module installed only if
an identical module is present in bay 3. Except in these cases (or in a case where you temporarily need to swap a failed I/O module in bay 1 or
3), bays 2 and 4 should be unoccupied.
Unless your system is configured according to these guidelines, do not perform any of the following actions:
 
 
 
Icon
Activity
Indicator Code
Indicator
Off
LAN is not linked.
 
Green
LAN is linked.
 
Off
LAN is not active.
 
Amber
Indicates that the system DRAC/MC and the LAN are communicating.
blinking
 
Off
The DRAC/MC is a backup for the master DRAC/MC.
 
NOTE:
For information on availability of dual (redundant) configurations for the DRAC/MC, see
www.dell.com.
 
Green
The DRAC/MC is active for system management.
 
Green
The DRAC/MC is in special or manufacturing mode.
blinking
 
Off
The DRAC/MC is operating normally.
Amber
In a single (nonredundant) configuration, this DRAC/MC failed. See your Installation and
Troubleshooting Guide for detailed information.
 
Amber
In a dual (redundant) configuration (when available), this DRAC/MC failed. See your Installation
blinking
and Troubleshooting Guide for detailed information.
None
Used for a serial connection with a null modem cable.
Table 1-9
provides information about the status indicators.