Dell PowerEdge 4400 Panduan Instalasi - Halaman 8

Jelajahi secara online atau unduh pdf Panduan Instalasi untuk Server Dell PowerEdge 4400. Dell PowerEdge 4400 20 halaman. Wake-on-lan (wol) support on dell servers
Juga untuk Dell PowerEdge 4400: Panduan Instalasi (42 halaman), Panduan Instalasi (28 halaman), Pemasangan Rak (37 halaman), Manual Pembaruan (8 halaman), Pembaruan Informasi (8 halaman), Panduan Pengguna (42 halaman), Pemasangan Rak (34 halaman), Panduan Pemasangan Perangkat Keras (40 halaman), Panduan Instalasi (36 halaman), Manual (15 halaman)

Dell PowerEdge 4400 Panduan Instalasi
(Rev. 11/3/98) FILE LOCATION: S:\SYSTEMS\SlimFast\ts\ProcUpgrade\028WD\028wdeb0.fm
1-4
Microprocessor Upgrade Installation Guide
,QVWDOOLQJ DQ 8SJUDGH 0LFURSURFHVVRU LQ
3RZHU(GJH 6\VWHPV
This section provides instructions for:
‡
Removing the cooling shroud, single-edge contact (SEC) cartridge, and heat sink
‡
Installing the new SEC cartridge and heat sink and replacing the cooling shroud
‡
Reassembling and checking the system
5HPRYLQJ WKH &RROLQJ 6KURXG 6(& &DUWULGJH DQG
+HDW 6LQN
1.
Turn off the system, including any attached peripherals, and disconnect the power
cable from the electrical outlet.
2.
Remove the right-side system cover and bezel.
See your system Installation and Troubleshooting Guide for specific instructions,
if needed.
3.
Remove the cooling shroud as follows:
a.
Unscrew and remove the two retention pins (see Figure 1-1).
b.
Remove the shroud by lifting the end of the shroud closest to the micropro-
cessor(s) until the opposite end of the shroud disengages from the cooling
fan on the system's back panel (see Figure 1-1).
DELL CONFIDENTIAL - Preliminary
9/11/00