Dell PowerEdge 6400 Manual - Halaman 4

Jelajahi secara online atau unduh pdf Manual untuk Server Dell PowerEdge 6400. Dell PowerEdge 6400 10 halaman. Wake-on-lan (wol) support on dell servers
Juga untuk Dell PowerEdge 6400: Pemasangan Rak (37 halaman), Panduan Instalasi Upgrade (42 halaman), Pemasangan Rak (34 halaman), Panduan Instalasi (42 halaman), Panduan Instalasi (37 halaman), Instalasi (4 halaman), Perakitan & Pemasangan (32 halaman), Manual (10 halaman), Manual (15 halaman)

Dell PowerEdge 6400 Manual
2
SCSI Backplane Option
7 .
Disconnect the flat data cable from the locking connector on the backplane
board.
8.
Disconnect the power cable labeled "HD-B/P" from the power connector on the
backplane board.
To release the connector, press the latch on the side of the connector.
9.
Disconnect the fan power cable from the power connector labeled "FAN" on the
backplane board.
To release the connector, press the latch on the side of the connector.
10. Loosen the captive thumbscrew on the backplane board.
11. Slide the SCSI backplane board away from the chassis inner wall approximately
1 centimeter (cm) (a quarter inch), and then lift the board off of the L-shaped
mounting tabs and away from the chassis (see Figure 1).
1
Thumbscrew
2
SCSI backplane board