Dell PowerEdge C6105 Panduan Teknis - Halaman 33

Jelajahi secara online atau unduh pdf Panduan Teknis untuk Server Dell PowerEdge C6105. Dell PowerEdge C6105 36 halaman. Rack server
Juga untuk Dell PowerEdge C6105: Gunakan Manual (46 halaman), Panduan Portofolio (27 halaman)

Dell PowerEdge C6105 Panduan Teknis
Resolution
1280 x 1024
1600 x 1200

Power supply specifications

Table 20 lists power supply specifications for the PowerEdge C6105.
Specification
Current consumption
Supply voltage
Frequency
Heat dissipation
Maximum inrush current

USB peripherals

The PowerEdge C6105 supports the following USB 2.0-compliant devices through the two front
ports:
DVD (bootable)
USB key (bootable)
Keyboard (only one USB keyboard is supported)
Mouse (only one USB mouse is supported)
33
Dell PowerEdge C6105 Rack Server Technical Guide
Refresh Rate (Hz)
60
60
Table 20.
Power supply specifications
1400W AC power supply
8.6–7.2A
200–240V AC
50/60Hz
5432 BTU/hour maximum
Initial in-rush current cannot
exceed 55A (peak). Secondary
inrush current cannot exceed
35A (peak).
Color Depth (bit)
32
32
1100W AC power supply
12.0–6.7A
100–240V AC (auto ranging)
50/60Hz
4575 BTU/hour maximum
Initial in-rush current cannot
exceed 55A (peak). Secondary
inrush current cannot exceed
35A (peak).