Cleaning and Maintenance
!
WARNING: THE DEVICE MUST BE ISOLATED FROM THE POWER SUPPLY
BEFORE ANY CLEANING AND MAINTENANCE TAKES PLACE.
!
CAUTION: ALWAYS WEAR SUITABLE GLOVES WHEN CLEANING.
• Use a dry cloth to clean the exterior of the device. Do not use any chemicals
or cleaners.
• The device may not operate effectively in very low temperatures. The
device can be damaged when exposed to sub-freezing temperatures.
Suggest operating temperature: -4°F~86°F, Suggest storage temperature:
-40°F~104°F.
• To extent the effective of the device, check the air inlet grill and air outlet
grills from time-to-time and clean them with a standard vacuum.
• Visually inspect the interior compartment of the device when the inside is
empty during the filter replacement process, if particulate has accumulated
in the device, clean the interior compartment of the device with a standard
vacuum.
• The power supply is specially adapted, please do not replace the
power supply without permission. The use of accessory equipment not
recommended by the manufacturer may cause an unsafe condition.
!
Contact a qualified electrician or customer support for cleaning and
maintenance instruction if your are unfamiliar with the device.
HEPA Filter Replacement
The filter should be replaced every 12 months or whenever indicated
by the flashing blue indicator. Depending on usage and contaminates
in the environment, the filter may need to be replaced before the
default cycle expires. When the air volume is reduced, replace the filter
to a new one.
Only use genuine DH Lifelabs Filter with your device. Use of any
other filter may compromise the proper operation of your device and
potentially void your warranty.
HEPA Filter Part No.: CA17FT-1
Contact customer support if you need to replace the filter.
NOTE: The HEPA filter is not washable. DO NOT immerse it in
water.
11
1. Make sure the device is power off.
2. Move the left and right pegs on the air intake grill to the middle to
release the air inlet grill.
3. Gently pull the air intake grill straight down, to access the filter.
Remove the used HEPA filter out by the pull tabs.
4.
Install a new HEPA filter inside the device. Ensure that any plastic
wrapping is removed from the filter prior to installing them in the
device.
NOTE: Ensure that the pull tabs are facing outward to facilitate
filter removal later.
5. Replace the air inlet grill back, and the two pegs will be locking in
place directly.
6. Turn on the device. After replacing the filter, press and hold down
the RESET button for 3 seconds to reset the filter life countdown. Once
filter reset is done, the flashing blue indicator light will changed to
green solid light.
HEPA filter replacment
Indicator
Blue light flashing
12