5. Enter the following command to identify the storage array and create a configuration file:
/usr/local/sbin/powervault_probe.py -i <ME4 IP address> -u <username> -p <password>
For example:
# powervault_probe.py -i 10.10.10.10 -u admin -p admin
The SA-STAG8-2U144 returns the following results:
Session Established
Model is ME4012
Using model file '/etc/solera/powervault/ME4012.json'
Configuration saved in config file '/etc/solera/powervault/config/powervault.10.10.10.10.json'
*******************************************************************************
Run the following command to configure the disk array
*******************************************************************************
powervault_config.py /etc/solera/powervault/config/powervault.10.10.10.10.json
The SA-STAG8-5U840 returns the following results:
Session Established
Model is ME4084
Using model file '/etc/solera/powervault/ME4084.json'
Configuration saved in config file '/etc/solera/powervault/config/powervault.10.10.10.10.json'
*******************************************************************************
Run the following command to configure the disk array
*******************************************************************************
powervault_config.py /etc/solera/powervault/config/powervault.10.10.10.10.json
6. Copy and paste the command from the previous step and enter it:
powervault_config.py /etc/solera/powervault/config/powervault.10.10.10.10.json
The SA-STAG8-2U144 returns the following results:
Session Established
Command completed successfully. - The host(s) were modified.
Command completed successfully. - The host(s) were modified.
Command completed successfully. - The host(s) were created.
Command completed successfully. - The host group(s) were created.
Command completed successfully. (2020-08-04 19:00:10)
Command completed successfully. (index) - The volume was created. (2020-08-04 19:00:12)
Mapping succeeded. Initiator 52cea7f043a38900 was mapped for volume index with LUN 1. (index)
(2020-08-04 19:00:15)
Command completed successfully. (index) - Mapping succeeded. Initiator 52cea7f043a38901 was
mapped for volume index with LUN 1. (2020-08-04 19:00:15)
Command completed successfully. (2020-08-04 19:00:17)
Command completed successfully. (capture) - The volume was created. (2020-08-04 19:00:19)
Mapping succeeded. Initiator 52cea7f043a38900 was mapped for volume capture with LUN 2. (capture)
(2020-08-04 19:00:21)
Command completed successfully. (capture) - Mapping succeeded. Initiator 52cea7f043a38901 was
mapped for volume capture with LUN 2. (2020-08-04 19:00:21)
Command completed successfully.