Dell PS4110 Panduan Pemilik Perangkat Keras - Halaman 11

Jelajahi secara online atau unduh pdf Panduan Pemilik Perangkat Keras untuk Server Dell PS4110. Dell PS4110 48 halaman. Storage arrays
Juga untuk Dell PS4110: Panduan Pengguna (20 halaman), Manual Perangkat Keras (50 halaman), Ikhtisar (7 halaman), Instalasi (2 halaman)

Dell PS4110 Panduan Pemilik Perangkat Keras

2 Maintaining Drives

You can replace a failed drive while the array remains running.

About Drive Types

Depending on your configuration, your array supports up to 24 2.5-inch SAS drives or up to 12 3.5-inch SAS
drives in internal drive bays.
Drives are connected to a backplane through drive carriers and are hot-swappable.
Drives are supplied in a carrier that is keyed to fit into specific array models, and cannot be installed in other
Dell arrays, or arrays not from Dell Inc.

Identifying Failed Drives

A drive failure is indicated by:
LEDs on the drive. See
A message on the console, in the event log, or in the Group Manager Alarms panel.
Indications in the Group Manager Member Disks window or the CLI
output.
Behind the bezel, arrays have a label showing the drive numbering for that specific array model:
In arrays with 2.5-inch drives (installed vertically in a row), the drives are numbered 0-23, left to right.
In arrays with 3.5-inch drives (installed horizontally), the drives are numbered from left to right and top to
bottom, starting with 0 on the upper left side.
Interpreting Drive LEDs on page
Table 3
Table 3: 3.5-inch Drive Numbering
3.5-inch Drive Numbering
0
4
8
8.
member select show disks
shows the drive order for the 3.5-inch drives.
1
2
3
5
6
7
9
10
11
command
7