Dell VEP4600 Setup Manual - Halaman 21

Jelajahi secara online atau unduh pdf Setup Manual untuk Server Dell VEP4600. Dell VEP4600 23 halaman.
Juga untuk Dell VEP4600: Panduan Instalasi (40 halaman), Panduan Instalasi (40 halaman)

Dell VEP4600 Setup Manual
Parameter
Table 2. Environmental parameters
Parameter
Operating temperature
Operating humidity
Storage temperature
Storage humidity
Maximum thermal output
Maximum operational altitude
Maximum non-operational altitude
Shock
Table 3. AC power requirements
Parameter
Power supply
Maximum current draw per system
Maximum power consumption*
Specifications
Back: 5 inches (12.7 cm)
Specifications
0°C to 45°C (23°F to 113°F) continuously
-5°C to 45°C (23°F to 113°F) short term
Short term is </= 1% of operational hours
per year.
NOTE:
Reduce maximum
temperature by 1°C/125 meters
(1°F/228 feet) above 950 meters
(3,117 feet).
5% to 90% (RH), non-condensing
–40° to 70°C (–40° to 158°F )
5% to 90%, non-condensing
500 W = 1706 BTU/Hr
10,000 feet (3,048 meters)
35,000 feet (10,668 meters)
Dell EMC Spec SV0115
Specifications
100–240 VAC 50/60 Hz
5A/4.17A at 100/120V AC 2.5A/2.1A at
200/240V AC
5-fan 16-core CPU: 300W
4-fan 8-core CPU: 230W
Specifications
21