Example 1-5: Setting the maximum bandwidth limit of VLANs
Ingress ports 1-20 (these ports are carrying a mixture of
VLAN2, VLAN3 and VLAN4 packets, either with or without VLAN tags)
mls qos enable
class-map cmap2
match vlan 2
class-map cmap3
match vlan 3
class-map cmap4
match vlan 4
mls qos enable
mls qos aggregate-police agg1 single-rate 256 3000 5000 exceed-action drop
mls qos aggregate-police agg2 single-rate 256 3000 5000 exceed-action drop
mls qos aggregate-police agg3 single-rate 256 3000 5000 exceed-action drop
policy-map pmap1
class cmap2
police aggregate agg1
class cmap3
police aggregate agg2
class cmap4
police aggregate agg3
interface port1.0.1-1.0.20
service-policy input pmap1
Page 6 | AlliedWare Plus™ OS How To Note: QoS
Port 24
1. Setting the egress rate