Dell EqualLogic PS4100XV Manual Perangkat Keras - Halaman 20
Jelajahi secara online atau unduh pdf Manual Perangkat Keras untuk Penyimpanan Dell EqualLogic PS4100XV. Dell EqualLogic PS4100XV 50 halaman. Equallogic ps series storage products
Juga untuk Dell EqualLogic PS4100XV: Ikhtisar (7 halaman)
7. control module 0
Figure 12. Cabling an iSCSI SAN-Attached Cluster to a Dell EqualLogic PS6510 Storage Array
1. cluster node 1
2. cluster node 2
3. switch 0
4. switch 1
Cabling The Dell EqualLogic PS5000/PS5500 Storage Arrays
1.
Connect a network cable from the network switch 0 to Ethernet 0 on the control module 1.
2.
Connect a network cable from the network switch 0 to Ethernet 1 on the control module 1.
3.
Connect a network cable from the network switch 1 to Ethernet 2 on the control module 1.
4.
Connect a network cable from the network switch 1 to Ethernet 0 on the control module 0.
5.
Connect a network cable from the network switch 1 to Ethernet 1 on the control module 0.
6.
Connect a network cable from the network switch 0 to Ethernet 2 on the control module 0.
7.
Repeat steps 1 to 6 to connect the additional Dell EqualLogic PS5000/PS5500 storage array(s) to the iSCSI switches.
For more information, see the figures below.
20
5. Dell EqualLogic PS6510 storage system
6. control module 1
7. control module 0