Dell EqualLogic PS4110XV Manual Perangkat Keras - Halaman 25
Jelajahi secara online atau unduh pdf Manual Perangkat Keras untuk Penyimpanan Dell EqualLogic PS4110XV. Dell EqualLogic PS4110XV 50 halaman. Equallogic ps series iscsi storage arrays with microsoft windows server failover clusters
Cabling Multiple iSCSI SAN-Attached Clusters For Dell EqualLogic PS6000/PS6100/PS6500 Storage Arrays
1.
Connect a network cable from the network switch 0 to Ethernet 0 on the control module 1.
2.
Connect a network cable from the network switch 0 to Ethernet 1 on the control module 1.
3.
Connect a network cable from the network switch 1 to Ethernet 2 on the control module 1.
4.
Connect a network cable from the network switch 1 to Ethernet 3 on the control module 1.
5.
Connect a network cable from the network switch 1 to Ethernet 0 on the control module 0.
6.
Connect a network cable from the network switch 1 to Ethernet 1 on the control module 0.
7.
Connect a network cable from the network switch 0 to Ethernet 2 on the control module 0.
8.
Connect a network cable from the network switch 0 to Ethernet 3 on the control module 0.
9.
Repeat steps 1 to 8 to connect the additional Dell EqualLogic PS6000/PS6100/PS6500 storage array(s) to the iSCSI
switches.
NOTE: For PS6100 storage array, having all eight cables in steps 1 through 4 provides highest level of cable
redundancy. It works fine with only four cables. You can skip either step 1 or 5, either step 2 or 6, either step 3 or 7,
and either step 4 or 8.
Obtaining More Information
For more information on configuring the cluster components, see the storage and tape backup documentation at
support.dell.com/manuals.
25