Dell PowerEdge SC420 Panduan Pemilik - Halaman 16

Jelajahi secara online atau unduh pdf Panduan Pemilik untuk Penyimpanan Dell PowerEdge SC420. Dell PowerEdge SC420 26 halaman. Expansion enclosure
Juga untuk Dell PowerEdge SC420: Manual Penggantian (14 halaman), Panduan Memulai (7 halaman), Pembaruan Informasi (21 halaman), Panduan Pemilik (21 halaman)

Dell PowerEdge SC420 Panduan Pemilik

Replacing Hard Drives

The SC400/SC420 expansion enclosures support hot-swappable hard drives.
The SC400 expansion enclosure supports up to 12 3.5-inch hard drives installed in a four-column, three-
row configuration. The SC420 expansion enclosure supports up to 24 2.5-inch hard drives installed
vertically side-by-side. Hard drives are connected to a backplane through hard drive carriers. Hard drive
blanks are installed in the hard drive bays that are not occupied.

SC400/SC420 Expansion Enclosure Drive Numbering

Drives are numbered from left to right in the SC400/SC420 expansion enclosure.
The Dell Storage Client identifies drives as XX-YY, where XX is the unit ID of the expansion enclosure, and
YY is the drive position inside the expansion enclosure.
The SC400 holds up to 12 drives, which are numbered from left to right in rows starting from 0 at the
top-left drive.
Figure 7. SC400 Expansion Enclosure Drive Numbering
The SC420 holds up to 24 drives, which are numbered from left to right starting from 0.
Figure 8. SC420 Expansion Enclosure Drive Numbering

Identifying the Failed Hard Drive

To determine which hard drive failed, use the Dell Storage Client.
1.
Click the Hardware tab.
2.
In the Hardware tab navigation pane, select and expand the failed storage system.
3.
In the Hardware Alerts area, find the hardware alert that identifies the enclosure with the failed hard
drive.
16