Dell PowerVault 201S Manual Petunjuk Penggantian - Halaman 5

Jelajahi secara online atau unduh pdf Manual Petunjuk Penggantian untuk Penyimpanan Dell PowerVault 201S. Dell PowerVault 201S 14 halaman. Dell powervault 20xs storage systems enclosure services expander module installation
Juga untuk Dell PowerVault 201S: Panduan Pemasangan Rak (26 halaman), Manual (9 halaman), Memperbarui (4 halaman), Konfigurasi (2 halaman), Panduan Instalasi (48 halaman)

Dell PowerVault 201S Manual Petunjuk Penggantian
1. Using a Phillips-head screwdriver, turn the two captive screws counter-
clockwise to release the power supply from the power-supply bay.
2. Holding the handle on the power supply, carefully pull the power supply out
of the power-supply bay (see Figure 5).
NOTE: The power-supply handle is provided to ease the task of pulling the
power supply free from the bay. Do not use the handle to carry the Dell
PowerVault 2xxS storage system.
Figure 5. Removing a Power Supply on a Redundant System
3. Repeat steps 1 and 2 to remove the remaining power supply.

Remove the Cooling Fans

NOTICE: In a nonredundant system, note that the cooling-fan blank
is located in the right cooling-fan bay. During the installation proce-
dure (found later in this document), you must return the cooling-fan
blank to the right cooling-fan bay.
NOTE: A redundant storage system has three cooling fans. A nonredundant
storage system has two cooling fans and one cooling-fan blank. Because a
cooling fan and a cooling-fan blank are removed in the same manner, both
components are referred to as a cooling fan in this procedure.
To remove the cooling fans from the storage system, perform the following
steps:
1. Using a Phillips-head screwdriver, turn the two captive screws counter-
clockwise to release the cooling fan from the cooling-fan bay.
Dell PowerVault 2xxS Storage Systems SCSI Backplane Board Replacement Instructions
captive screws (2)
5