1. Inspect the
system status LEDs
2. Turn off the system, including any attached peripherals.
3. If the system is connected to a power distribution unit (PDU), turn the PDU off and then on again.
If the system is not receiving power, plug the PDU into another electrical outlet. If it still is not receiving power, try
another PDU, and then reconnect the system to the electrical outlet or PDU.
4. Inspect the exterior of the system, including all controls and indicators, and all user-accessible data storage devices
for any signs of physical damage.
Does the inspection reveal any problems?
Yes. Proceed to the appropriate procedure in
No. Proceed to
"Observing the Boot

Observing the Boot Routine

NOTE:
To observe the boot routine, you must use the console redirection function on the serial port (COM1). See
the System Administrator's Guide for more information about console redirection.
Looking at and listening to the system are important in determining the source of a problem. Look and listen during the
system's startup routine for the indication described in Table 1.
Table 1. Startup Routine Indications
Look and Listen for:
An error message (through console redirection) See
The hard drive activity indicators
A series of beeps
An unfamiliar constant scraping or grinding
sound when you access a hard drive

Internal Visual Inspection

NOTICE:
Before you proceed with the internal visual inspection described in this section, ensure that the user has
saved all open files and exited all open application programs, if possible, to prevent loss of data.
A simple visual inspection of a system's interior hardware can often lead to the source of a problem, such as a loose
expansion card, cable connector, or mounting screw. When you perform the visual inspection, see
locate components referenced in the inspection procedure.
To perform the internal visual inspection, perform the following steps:
1. Turn off the system, including any attached peripherals, and disconnect all the power cables from electrical outlets.
CAUTION:
Before beginning to work inside the system, disconnect the power supply from the power
source and the power supply cables from the power supply.
2. Remove the system cover as described in
CAUTION:
The microprocessor and heat-sink assembly can get extremely hot during system operations.
Be sure that it has had sufficient time to cool before touching it.
CAUTION:
When handling the microprocessor and heat-sink assembly, take care to avoid sharp edges
on the heat sink.
3. Verify that the memory modules, expansion cards, and microprocessor and heat-sink assembly or assemblies are
fully seated in their sockets or connectors.
4. To remove and reseat a microprocessor and heat-sink assembly, perform the steps described in "Microprocessor."
5. To remove and reseat a memory module, perform the steps described in
for an indication of component malfunction.
"Removing and Replacing
Routine."
Action
"Codes, Error Messages, and
See
"Codes, Error Messages, and
See
"Codes, Error Messages, and
See
"Hard
Drives" in
"System
Cover."
Parts."
Indicators."
Indicators."
Indicators."
"Removing and Replacing
"Memory
Modules."
Parts."
"System
Features" to