Juga untuk Dell PowerVault MD3200i Series: Panduan Penyebaran (41 halaman), Manual Pembaruan (32 halaman), Petunjuk Pemasangan Rak (2 halaman), Matriks Dukungan (12 halaman), Panduan Instalasi (18 halaman), Pembaruan Informasi (1 halaman), Matriks Dukungan (11 halaman), Matriks Dukungan (17 halaman), Buku Panduan Teknis (38 halaman), Buku Putih (22 halaman), Manual (16 halaman)

Dell PowerVault MD3200i Series Panduan Pengguna
Figure 30. vCenter Plug-in Log File
Additional log files are also maintained in this directory that are useful for
technical support to resolve issues, but are generally not user friendly format.
vcenter2debug-x.log.y—Debug log used by technical support
jetty-service.log—Jetty service log, used by technical support
<date/time stamp>.request.log—Log of IP addresses for all Jetty
service requests from clients

Common Errors

The most common errors encountered are:
Unable to communicate with Application Server
Check firewall settings to ensure the Jetty TCP port is enabled.
Verify the cimserver/Pegasus server service is started on the
Application Server. — Verify the Jetty6-Service is started on the
Application Server.
Unable to create/delete objects
Verify the current user ID has correct storage administrator privileges
assigned to their role.