Dell PowerVault NX3100 Panduan Pemecahan Masalah - Halaman 7

Jelajahi secara online atau unduh pdf Panduan Pemecahan Masalah untuk Penyimpanan Dell PowerVault NX3100. Dell PowerVault NX3100 17 halaman. Document
Juga untuk Dell PowerVault NX3100: Manual Pembaruan (32 halaman), Menyiapkan (2 halaman), Panduan Administrator (50 halaman)

Dell PowerVault NX3100 Panduan Pemecahan Masalah
Table 1. Installation Issues
Issue
Error: -5003.
Error occurred
while
attempting to
create OS
volume.
(continued)
Description
Invalid operating system
drive configuration. The
layout of physical disks to
be used as the operating
system disks does not
meet the required layout
for the device.
Workaround / Solution
To workaround this issue, perform
one of the following steps:
• Ensure that all drives in the
operating system drive slots are
correctly attached and do not
have data on them. Physical disks
for the operating system must be
of the same type and must be
greater than 80 GB.
• Enter the PERC BIOS during the
operating system boot operation
and ensure that there are no
foreign configurations, drives are
clean of all data, the drives meet
the minimum size requirement,
and are fully functioning and
accessible. For more information,
see the PERC documentation at
support.dell.com/manuals.
Troubleshooting Guide
7