Dell 1N25N Meningkatkan Firmware - Halaman 5
Jelajahi secara online atau unduh pdf Meningkatkan Firmware untuk Beralih Dell 1N25N. Dell 1N25N 14 halaman.
Firmware Upgrade Procedure Dell™ Networking N2100 Series Switches
How to Access Serial Console on N2128PX-ON Series switches
NOTE:
How to access serial console of the N2128PX-ON Series switch? Use a supplied "RJ45 Yost
to DB9 serial cable" to access the serial console. Connect the RJ45 end of the cable to the RJ45 serial
console port and the DB9 connector to your PC. Download and Install the terminal emulation software on
your PC (for example, PuTTY) to access the serial console with the correct settings (default setting 115200
baud, 8 data bits, no parity bit, 1 stop bit, and no flow control).
Figure.1 N2128PX-ON Switch Console Port Location
Upgrading Example for Dell Networking N2128PX-ON Series Switches
This example shows an annotated upgrade example for a N2128PX-ON switch. This example presumes the
administrator is logged in to the switch or stack via Serial console. You can also follow this upgrade procedure via
telnet or SSH after setting enable password if it is not set so.
1. Back up your configuration. The following commands copy the running-config to a TFTP server:
console#copy running-config tftp://10.10.10.200/myconfig.txt
Mode........................................... TFTP
Set TFTP Server IP............................. 10.10.10.200
TFTP Path...................................... ./
TFTP Filename.................................. myconfig.txt
Data Type...................................... Config Script
Source Filename................................ running-config
Management access will be blocked for the duration of the transfer
Are you sure you want to start? (y/n) y
11062 bytes transferred
File transfer operation completed successfully.
console#
2. Set an enable password and save the configuration (not required if an alternative enable authentication
method is already configured).
console#configure
console(config)# enable password <password>
console(config)# exit
console# copy running-config startup-config
3. Download the 6.3.6.9 firmware image from a TFTP server.
console#copy tftp://10.10.10.200/N2100v6.3.6.9.stk backup
Transfer Mode.................................. TFTP
Server IP Address.............................. 10.10.10.200
Source File Path............................... ./
Source Filename................................ N2100v6.3.6.9.stk
Data Type...................................... Code
Destination Filename........................... backup
Management access will be blocked for the duration of the transfer
Are you sure you want to start? (y/n) y
TFTP Code transfer starting...
27459957 bytes transferred...
File contents are valid. Copying file to flash...
Attempting to send the STK file to other units in the stack...
File transfer operation completed successfully.
Page 3