Juga untuk Dell PowerEdge M520: Pembaruan Informasi (38 halaman), Catatan Rilis (27 halaman), Manual (25 halaman), Panduan Pengguna (23 halaman), Panduan Informasi Penting (35 halaman), Manual Pembaruan (32 halaman), Manual Pembaruan (28 halaman), Panduan Pengguna (22 halaman), Panduan Memulai (12 halaman), Panduan Teknis (46 halaman), Panduan Teknis (45 halaman), Panduan Portofolio (27 halaman), Panduan Memulai (14 halaman), Panduan Memulai (12 halaman)

Dell PowerEdge M520 Panduan Pengguna
Dell 10Gb Ethernet Pass Through II
4
Operating Procedures
4.1

Procedure for Updating Software

The 10GbE PTM consists of three PhyX® devices and a micro-controller (CPU). This procedure
describes how to update both CPU SW & PhyX® FW using a single .pfw binary file.
The 10GbE PTM is delivered with the latest firmware available at the time of production. New fir-
mare versions will be posted on the Dell support page. The latest firmware can be found at:
http://support.dell.com/support/
Step 1. Download the 10GbE PTM firmware .zip file and extract the .pfw binary file.
Step 2. Connect to the 10GbE PTM using an SSH Client as described in
the 10GbE PTM CLI," on page
Step 3. From the CMC command line, connect to the 10GbE PTM CLI. Enter:
Note:
At least 20 seconds must have passed since the last power cycle of the 10GbE PTM
module before running the following connect command.
$ connect switch-<n>
where <n> is the number of the switch -- 2 in our example.
The prompt should change to #.
Step 4. To start the upgrade process, run the command:
# copy image from-file
The system will now wait for a ".pfw" file to be transferred from the SSH client.
Step 5. In your SSH client, initiate file transfer by pulling down the Transfers menu and clicking
Send Files. Provide the path to the ".pfw" file and send it.
8.
Rev 1.00
Section 2, "Connecting to
19