Switch configuration (OS 9.x)
2.4.4
Configure stack on the second switch
Dell>enable
Dell#stack-unit 1 renumber 2
Note: After confirming the configuration change, the switch will need to reboot.
Dell#configure
Dell(conf)#stack-unit 2 priority 1
Dell(conf)#stack-unit 2 stack-group 12
Dell(conf)#stack-unit 2 stack-group 13
Dell(conf)#exit
Dell#copy running-config startup-config
Dell#reload
2.4.5
Verify stack configuration
From the first switch (master) CLI, confirm that the stack has formed.
Dell#show redundancy
Dell#show boot system stack-unit all
Note: The MASTER LED on the switch front panel will show a steady light for the master unit and a blinking
light for the standby unit. All of the following configuration steps must be performed from the master switch.
2.4.6
Configure out of band (OOB) management port
Dell#config
Dell(conf)#interface ManagementEthernet 1/1
Dell(conf-if-ma-1/1)#no shutdown
Dell(conf-if-ma-1/1)#ip address <ipaddress> <mask>
Dell(conf-if-ma-1/1)#no shutdown
Dell(conf-if-ma-1/1)#exit
2.4.7
Configure route for OOB management port (optional)
Dell(conf)#management route <X.Y.Z.0> /24 <A.B.C.1>
Note: In the previous command, <X.Y.Z.0> is the network your management system is connecting from and
<A.B.C.1> is the gateway for the switch. If your management system is on the same subnet as the switch, the
previous step may be omitted. The prior example assumes a class C subnet mask.