Table 14. Environmental parameters
Parameter
Operating temperature
Operating humidity
Storage temperature
Storage humidity
Maximum thermal output
Maximum operational altitude
Maximum non-operational altitude
Shock
Table 15. AC power requirements
Parameter
Power supply
Maximum current draw per switch
Maximum power consumption
Typical power consumption
Table 16. DC power requirements
Parameter
Minimum and maximum input voltage range
Input power at full load
Input current at full load
Start up VDC—voltage when the switch is powered on
Start off VDC—voltage during the boot-up process
Specifications
5° to 40°C (50°F to 104°F)
-5°C to 45°C (23°F to 113°F) short term
Short term is </= 1% of operational hours per year.
NOTE:
Reduce maximum temperature by 1°C/125 meters
(1°F/228 feet) above 950 meters (3,117 feet).
5% to 85% (RH), non-condensing, continuously
5% to 90% (RH), non-condensing, short term
Short term is </= 1% of operational hours per year.
–40° to 65°C (–40°F to 149°F)
5% to 95%, non-condensing
470 W = 1260 BTU/Hr
10,000 feet (3,048 meters)
39,370 feet (12,000 meters)
SV0115 — ODM
Specifications
100–240 VAC 50/60 Hz
4.7A/3.9A at 100/120V AC 2.35A/1.95A at 200/240V AC
370 Watts
200 Watts
Specifications
−40.5V, –48V, -60V
−40.5V/970W −48V/930W −60V/ 950W, without fan
−40.5V/980W −48V/940W −60V/ 960W, with fan
−40.5V/23.8A −48V/19.0A −60V/ 15.6A, without fan
−40.5V/24.0A −48V/19.2A −60V/ 16.0A, with fan
39.0+/−1.5 V
37.5+/−1.5 V
Specifications
41