1. Removal of 32 oz. Tank. Rotate the dial of the tank lock towards
the unlock position. Pull the tank release ring and carefully
remove the tank. Hold on to the tank while pulling the ring or the
tank may fall.
1
2. Diluting PURTABS into the tank. Fill the tank up to the fill line
with warm water. Drop the number of tablets needed into the
tank. Close the tank with the lid, and wait for complete
dilution prior to re-inserting the tank. Check visually to
confirm dilution. Label the date of dilution on the tank.
Please reference the dilution table for concentrations.
3. Inserting tank back into sprayer. Place the tank on a flat surface,
and align the groves of the tank with the sprayer. Insert the
tank into the sprayer until you hear the click of the release ring
locking back into place. Rotate the dial of the tank lock towards
the lock position to secure the tank in place.
4. Electrostatic on/off. Turn on the electrostatic component by
sliding it to the "on" position.
1
Locking the trigger: Press on the trigger lock to engage the lock prior to removing the tank, storing
the sprayer, and in between uses.
5. Optimal distance. To ensure optimal electrostatic performance
always keep your hand firmly wrapped around the handle and in
contact with the ground strap. Keep a distance of 2-3 feet from
desired surface. Pull the trigger and spray.
6. Care instructions.
Never store the sprayer with a full tank.
Remove tank, prior to storing the sprayer, and use the tank lid to
seal any remaining PurTabs solution for the next use. Regularly
flush the sprayer and nozzle by filling the tank with warm water
and spraying each nozzle setting for approximately 30 seconds.
Evacuate water fully from sprayer tubing prior to storing. Wipe
nozzle area dry after each use.
7. Nozzle care. "Do not touch or insert foreign
object into the nozzle to avoid electric shock". If
your single becomes clogged, soak in hot soapy
water and blow out with pressurized air to
remove blockage. When not properly cleaned,
the sprayer nozzle residual chemical deposits
build up. Deposit build up results in decreased
bar pressure and decreased spray patterns.
© EarthSafe Chemical Alternatives, LLC. All rights reserved.