Miele PW 811 Rencana Instalasi - Halaman 12
Jelajahi secara online atau unduh pdf Rencana Instalasi untuk Mesin cuci Miele PW 811. Miele PW 811 38 halaman.
Installation and planning notes
Cold water
connection
12
Water connection
This appliance must be installed according to AS/NZS 3500.1. This
appliance has been supplied with a separate backflow prevention
device. This machine must be connected to the potable water
supply via the non-return valve (dual check valve) supplied with the
machine.
The water flow pressure must be at least 1 kPa and should not
exceed 1000 kPa. If it is exceeds 1000 kPa, a pressure reducing valve
must be used.
The machine must be connected to the water supply using the inlet
hoses provided.
The connection points are subject to water supply pressure.
Turn on the tap slowly and check for leaks.
Correct the position of the washer and union if necessary.
Use the inlet hose supplied (cold - blue stripes) for the cold water
connection. For cold water connection, 2 x ¾" thread is required. If
there is only 1 cold water connection use the Y-piece supplied. If this
is not available, only a qualified installer may connect the washing
machine to the mains water supply.
The inlet hose for cold water (blue stripes) is not intended to be
used for a hot water connection.
If the hot or hard water connection is missing, cold water
consumption increases accordingly to account for the missing water
intake.
A non-return valve supplied separately with the machine must be
connected to the tap for both hot and cold water connection.
Install the dual check valve provided
between the water tap and Y-piece.
A Y-piece for connecting two inlet tubes to a single cold water line is supplied.
PW 811 / PW 814 / PW 818