Miele G 1 Series Manual - Halaman 5

Jelajahi secara online atau unduh pdf Manual untuk Mesin pencuci piring Miele G 1 Series. Miele G 1 Series 46 halaman.
Juga untuk Miele G 1 Series: Manual (14 halaman)

G 1xxx/G 2xxx
Options:
Function
Reset
Water hardness setting
Dispensed rinse aid
quantity setting
Buzzer on/off
Resetting standard
settings
Programming
Press the Program button
1x. To reset all parameters
to standard settings, press
and hold the Program
button until the
"Intake/Drain" LED lights
up. Then briefly press the
Program button.
Briefly press Program 2x.
To set the desired water
hardness, press and hold
the Program button until
the "Intake/Drain" LED
lights up. Then select the
desired value by briefly
pressing the Program
button as appropriate.
Briefly press Program 3x.
To set the desired
quantity, press and hold
the Program button until
the "Intake/Drain" LED
lights up. Then select the
desired value by briefly
pressing the Program
button as appropriate.
Briefly press the Program
button 4x. To make the
desired setting, press and
hold the Program button
until the "Intake/Drain"
LED lights up. Then select
the desired setting by
briefly pressing the
Program button as
appropriate.
Briefly press Program
12x. To reset all
parameters to standard
settings, press and hold
the Program button until
the "Intake/Drain" LED
lights up. Then briefly
press the Program button.
5
Technical Information
Display
The "Intake/Drain" LED flashes 1x
rapidly. "SaniWash" LED is off:
values do not correspond to
standard settings; "SaniWash" LED
flashes: values correspond to
standard settings.
The "Intake/Drain" LED flashes 2x
rapidly at intervals. The set value is
indicated by the "SaniWash" LED
flash pattern. If the "SaniWash" LED
flashes 4x rapidly at intervals, this
corresponds to the standard setting
of 12 - 15°d (12.8 - 16.1 gpg); see
2
Table 3.
The "Intake/Drain" LED flashes 3x
rapidly at intervals. The set value is
indicated by the "SaniWash" LED
flash pattern. If this LED flashes 3x
rapidly at intervals, this corresponds
to the standard setting of 0.1 fl.oz.
(3mL). Range: 0 - 0.2 fl.oz. (0 - 6
mL); see Table 4.
The "Intake/Drain" LED flashes 4x
rapidly at intervals. "SaniWash"
LED is off: Buzzer on (standard
setting). "SaniWash" LED flashes:
Buzzer off.
The "Intake/Drain" LED flashes 1x
slowly and 2x rapidly at intervals.
This programmable function can be
used to reset all parameters that can
be modified by the customer to
standard settings. If the "SaniWash"
LED is off, the values do not
correspond to standard settings. If
the "SaniWash" LED flashes, the
values correspond to standard
settings.