Allmatic CT3IND Panduan Untuk Instalasi - Halaman 4
Jelajahi secara online atau unduh pdf Panduan Untuk Instalasi untuk Unit Kontrol Allmatic CT3IND. Allmatic CT3IND 10 halaman. Programmable control board for sliding gates
COM.
21
11
CLOSE.
25
COM.
21
12
STOP
26
COM.
21
L.S.OP.
13
27
L.S.CL.
28
30
14
29
COM.
31
PHOTO1
15
32
PHOTO2
33
-
-
+
36
36
36
+
+
16
-
35
35
35
-
+
-
34
34
34
37
EDGE 1
38
17
39
EDGE 2
40
41
18
24 Vac
42
43
19
~
44
45
V
43
U
~ ~ ~
44
W
45
6-1622598
REV.3
23/09/2020
CLOSE INPUT
Connect the button CLOSE between the clamp
21 and 25 of the control unit.
ATTENTION: Leave it open if not used.
STOP INPUT
Connect the NORMALLY CLOSED contact of
the STOP between the clamp 21 and 26 of the
terminal box.
ATTENTION: jumper the input 21 to the input
26 if not used.
LIMIT SWITCHES INPUTS
Connect the NORMALLY CLOSED contact of the
OPENING LIMIT SWITCH (L.S.OP.) between the
clamp 21 and 27 of the terminal board.
Connect the NORMALLY CLOSED contact of the
CLOSING LIMIT SWITCH (L.S.CL.) between the
clamp 21 and 28 of the terminal box.
The automation can not work without limit
switches.
ANTENNA INPUT
•
Connect the signal cable to the clamp 29 of
the control unit.
•
Connect the earth of the antenna to the clamp
30 of the control unit.
PHOTOCELLS INPUT
Connect the NORMALLY CLOSED contact of
the photocell 1 (PHOTO1) between the clamp
31 and 32 of the terminal box.
Connect the NORMALLY CLOSED contact of
the photocell 2 (PHOTO2) between the clamp
31 and 33 of the terminal box..
ATTENTION: jumper the inputs 32 and 33 to
the clamp 31 if not used
PHOTOCELLS POWER SUPPLY
•
Connect the clamp 36 of the control unit to
the clamp + of power supply
photocell's transmitter.
•
Connect the clamp 35 of the control unit to the
clamp -
of power supply for the photocells
receiver and transmitter.
•
Connect the clamp 34 of the control unit to
the clamp + of power supply for the photocells
receiver.
SAFETY EDGE INPUTS
Connect the safety edge 1 between the clamps
37-38 and the safety edge 2 between the
clamps 39-40.
The safety edge contact must be normally
closed or resistive 8K2 depending on the
selection.
Acccessories output 24 Vac 3W.
Connect the 230 Vac SINGLE PHASE motor
between the clamps 43 - 44 - 45.
Connect the neutral on the clamp 43, phase 1
on the clamp 44, phase 2 on the clamp 45 and
the capacitor between clamps 44 and 45.
In case that a THREE PHASE 400 Vac motor
is used, connect the three phases to the clamps
43, 44 and 45.
ITA
ENG
FRA
Before actioning the installation ensure that the limit
switches are functioning and correctly cabled.
The presence of the metallic parts or humidity in the
walls could have negative influences on the range
of the system. We suggest therefore to not place
the receiving antenna and/or transmitters near big
metallic objects, near the floor or on the ground.
The functioning of the PHOTOCELLS can be set
Entering the menu
The photocells test is enabled by the menu
for the
ATTENTION: the control unit supplies a voltage of
24 Vdc and can supply a maximum power of 3W.
For the safety edges test connect the test device of
the edge on the power supply pin TX (test activated
with low logical signal 0Vdc.)
Select the type of security edge used (mechanical or
8K2) through the menu
The inputs, if are not used, must be jumpered in
case of selection of mechanical safety edge or, they
have to be closed through a 8.2K resistance
(supplied ) in case of the safety edge 8K2.
Before activating the automatism check that the
wiring of the motor is compliant with the installation.
To do this, follow the procedure of the preliminary
checks.
ESP
DEU
POR
and
and
!!! Risk of electric shock !!!
4 / 10