Miele DA 1255 Petunjuk Pengoperasian dan Pemasangan - Halaman 29
Jelajahi secara online atau unduh pdf Petunjuk Pengoperasian dan Pemasangan untuk Kap Ventilasi Miele DA 1255. Miele DA 1255 48 halaman.
Safety distance between hob and cooker hood (S)
When planning the installation height of your cooker hood, the minimum safety
distance between the top of a cooker or hob and the bottom of the cooker hood
is as follows, unless a greater distance is specified by the manufacturer of your
cooking appliance.
See "Warning and Safety" instructions for further information.
Cooking appliance
Electric hob
Electric grill, deep fat fryer (electric)
Multi-burner gas hob,
total output ≤ 12.6 kW, no burner > 4.5 kW
Multi-burner gas hob,
total output > 12.6 kW and ≤ 21.6 kW,
no burner > 4.8 kW.
Multi-burner gas hob,
total output > 21.6 kW,
or multi-burner gas hob where one burner > 4.8 kW.
Single burner gas hob, output ≤ 6 kW.
Single burner gas hob, output > 6 kW and ≤ 8.1 kW.
Single burner gas hob, output > 8.1 kW
Installation
Minimum distance S
450 mm
650 mm
650 mm
760 mm
Not possible
650 mm
760 mm
Not possible
29