Connection for air extraction
Condensate trap
In addition to insulating the exhaust
ducting, we recommend that a suitable
condensate trap is also installed to
collect and evaporate any condensate
which may occur.
Condensate traps for 125 mm or
150 mm ducting are available as
optional accessories.
When installing a condensate trap,
ensure that it is positioned vertically
and as closely as possible above the
exhaust socket.
The arrow on the housing indicates
the direction of air-flow.
40
Silencer
To achieve even further reductions in
noise levels, a special silencer (optional
accessory) can be fitted in the ducting
system.
Extraction mode
The silencer not only reduces noise
from the motor outside the house, but
also sounds from outside (e.g. traffic
noise). For this reason the silencer must
be positioned as close as possible to
the ducting exit .