Installation

Before installation

Before installation, it is important
to read the information given on the
following pages as well as the
"Warning and Safety instructions" at
the beginning of this booklet.
The rangehood is intended to be built
into wall units, rangehood housing
units, and above breakfast bars or
island areas.
 Check prior to installation that the top
of the appliance will be accessible
after installation.
If this is not the case, install the exhaust
ducting and prepare the mains
connection before installation.

Installation materials

1 exhaust connection
for exhaust ducting  150 mm.
1 non-return flap
for fitting into the exhaust connection
on the motor unit (not needed for
recirculation mode). Depending on
model, the non-return flap may already
be fitted.
24
4 M5 x 40 mm screws, 4 washers,
4 M5 nuts for securing the rangehood
to an interim shelf.
10 M4 x 8 mm screws for securing the
rangehood.
4 M4 x 12 mm screws for additional
securing of the rangehood to uneven
surfaces.
Conversion kit for recirculation
mode
including directional unit, aluminium
hose and hose clips (the conversion kit
is not supplied and must be purchased
separately. See "Technical data").