Miele DA 249-4 Petunjuk Pengoperasian dan Pemasangan - Halaman 29

Jelajahi secara online atau unduh pdf Petunjuk Pengoperasian dan Pemasangan untuk Kap Ventilasi Miele DA 249-4. Miele DA 249-4 40 halaman. Ventilation system
Juga untuk Miele DA 249-4: Petunjuk Pengoperasian dan Pemasangan (40 halaman), Petunjuk Pengoperasian dan Pemasangan (40 halaman), Petunjuk Pengoperasian dan Pemasangan (44 halaman)

Miele DA 249-4 Petunjuk Pengoperasian dan Pemasangan
Safety distances between cooktop
and rangehood (S)
The minimum safety distances
between the top of a cooktop and
the bottom of the rangehood are
as follows, unless a greater
distance is specified by the
manufacturer of your cooking
appliance:
Cooking appliance
Electric cooktop
Open electric grill
Deep fat fryer (electric)
Multi-burner gas cooktop
with maximum 45.4 MJ/h
total output, with no burner
having a greater output
than 16.2 MJ/h.
Multi-burner gas cooktop
with total output greater
than 45.4 MJ/h, or a gas
cooktop including a single
burner with an output
greater than 16.2 MJ/h.
Single gas cooktop with a
maximum output of
21.6 MJ/h
Single gas cooktop with a
maximum output greater
than 21.6 MJ/h
See "Warning and Safety"
instructions for further information.
– When deciding on the safety
distance between the cooktop and
rangehood, please note that a
distance of 650 mm above electric
cooktops may be preferable to give
more working space under the
rangehood.
– Account should also be taken of the
height of the person who will be
using the rangehood most often. The
person should have sufficient space
Distance
to work comfortably at the cooktop,
S
and also be able to reach the
rangehood controls with ease.
600 mm
– If positioned too high, extraction will
650 mm
be inefficient.
650 mm
– The height of the cooking appliance
650 mm
must be taken into account when
planning the installation height of the
rangehood.
760 mm
650 mm
760 mm
Appliance dimensions
29